American Peptidestandards & methods

Method · reference tier · beta

Blend screen

Two schematic profiles overlap a shaded screening window, illustrating a comparison of blend properties.
CC BY 4.0 · Rules

Open the interactive blend calculator on AmericanPeptide.com · Module: packages/calculators/blend-screen.ts · Checked against american-peptide d35605d66498

What it answers

The blend draw still counts doses. This screen is the extra pass the beta tool runs after a catalog peptide is chosen. It estimates whether peptides that are already in solution are likely to associate, and it repeats the incompatibilities written on a product label.

The website resolves a slug against its catalog, then passes the sequence and a copper flag into this module. The catalog stays in the application repository. A row with a name and no sequence is reported as unresolved. Charge, pI, and GRAVY are skipped for that row.

Rules

Buffer pH defaults to 5.7 and is clamped to [0, 14]. Charge is Henderson–Hasselbalch with the Lehninger pKa set (N-terminus 9.69, C-terminus 2.34, C 8.33, D 3.65, E 4.25, H 6.00, K 10.53, R 12.48, Y 10.07). The isoelectric point is the bisection zero of that charge on [0, 14]. GRAVY is the mean Kyte–Doolittle hydropathy.

near the pI               |pI − pH| ≤ 1
opposite charge           both |z| ≥ 0.5 and the signs differ
strongly hydrophobic      GRAVY ≥ 0.5
fibril slugs              glucagon, amylin, insulin
labeled pair              pramlintide + insulin
copper–thiol              copper flag on one row, cysteine on the other

Levels are warn, then caution, then info. Three standing notes always travel with the result: do not co-store a blend, swirl rather than shake, and keep warned pairs in separate syringes. Those notes are cautions. They are not a mixing procedure.

Worked examples

Pramlintide and insulin at pH 5.7 raise labeled-incompatibility. The detail cites the Symlin prescribing information: do not mix them in the same syringe. Glucagon at the same pH raises fibril. Pramlintide’s sequence contains cysteines, so cysteine fires with it.

GHK-Cu (sequence GHK, copper flag set) and BPC-157 at pH 7.4 carry opposite net charge, so opposite-charge fires. BPC-157 has no cysteine, so copper-thiol does not. Passing the buffer as BPC-157’s own pI raises near-pi. Two copies of glucagon do not raise opposite-charge.

Assumptions

  • Each peptide is already dissolved. The screen does not choose a diluent or a mixing order.
  • The sequence is the unmodified single-letter chain. Fatty-acid chains, disulfides, and amidation do not change the charge.
  • A copper complex is a caller-supplied flag. GHK alone does not imply copper.
  • Fibril and labeled-pair rules match catalog slugs, not display names.
  • The draw math and this screen do not feed each other. An over-fraction warning does not change a charge flag, and a gel flag does not change the dose count.

Edge cases

  • A non-finite pH falls back to 5.7. Values outside 0–14 clamp to the nearer end.
  • An empty sequence with a slug still participates in slug rules and records no-sequence.
  • A typed name with no slug and no sequence is listed under unresolved and is skipped.
  • Chain labels in a stored sequence are stripped to letters, so insulin’s A and B chains are scored as one string.

Scope note

Sequence arithmetic and a short list of labeled incompatibilities. This is a hypothesis, not a formulation study and not a dosing recommendation. A clear screen does not mean the peptides can share a vial.

Blend draws · All methods